ClickHouse коннектор#

Примечание

Ниже приведена оригинальная документация Trino. Скоро мы ее переведем на русский язык и дополним полезными примерами.

The ClickHouse connector allows querying tables in an external ClickHouse server. This can be used to query data in the databases on that server, or combine it with other data from different catalogs accessing ClickHouse or any other supported data source.

Requirements#

To connect to a ClickHouse server, you need:

  • ClickHouse (version 21.8 or higher) or Altinity (version 20.8 or higher).

  • Network access from the Trino coordinator and workers to the ClickHouse server. Port 8123 is the default port.

Конфигурация#

The connector can query a ClickHouse server. Create a catalog properties file that specifies the ClickHouse connector by setting the connector.name to clickhouse.

For example, to access a server as clickhouse, create the file etc/catalog/clickhouse.properties. Replace the connection properties as appropriate for your setup:

connector.name=clickhouse
connection-url=jdbc:clickhouse://host1:8123/
connection-user=exampleuser
connection-password=examplepassword

The connection-url defines the connection information and parameters to pass to the ClickHouse JDBC driver. The supported parameters for the URL are available in the ClickHouse JDBC driver configuration.

The connection-user and connection-password are typically required and determine the user credentials for the connection, often a service user. You can use secrets to avoid actual values in the catalog properties files.

Примечание

Trino uses the new ClickHouse driver(com.clickhouse.jdbc.ClickHouseDriver) by default, but the new driver only supports ClickHouse server with version >= 20.7.

For compatibility with ClickHouse server versions < 20.7, you can temporarily continue to use the old ClickHouse driver(ru.yandex.clickhouse.ClickHouseDriver) by adding the following catalog property: clickhouse.legacy-driver=true.

Connection security#

If you have TLS configured with a globally-trusted certificate installed on your data source, you can enable TLS between your cluster and the data source by appending a parameter to the JDBC connection string set in the connection-url catalog configuration property.

For example, with version 2.6.4 of the ClickHouse JDBC driver, enable TLS by appending the ssl=true parameter to the connection-url configuration property:

connection-url=jdbc:clickhouse://host1:8443/?ssl=true

For more information on TLS configuration options, see the Clickhouse JDBC driver documentation

Data source authentication#

The connector can provide credentials for the data source connection in multiple ways:

  • inline, in the connector configuration file

  • in a separate properties file

  • in a key store file

  • as extra credentials set when connecting to Trino

You can use secrets to avoid storing sensitive values in the catalog properties files.

The following table describes configuration properties for connection credentials:

Property name

Description

credential-provider.type

Type of the credential provider. Must be one of INLINE, FILE, or KEYSTORE; defaults to INLINE.

connection-user

Connection user name.

connection-password

Connection password.

user-credential-name

Name of the extra credentials property, whose value to use as the user name. See extraCredentials in Parameter reference.

password-credential-name

Name of the extra credentials property, whose value to use as the password.

connection-credential-file

Location of the properties file where credentials are present. It must contain the connection-user and connection-password properties.

keystore-file-path

The location of the Java Keystore file, from which to read credentials.

keystore-type

File format of the keystore file, for example JKS or PEM.

keystore-password

Password for the key store.

keystore-user-credential-name

Name of the key store entity to use as the user name.

keystore-user-credential-password

Password for the user name key store entity.

keystore-password-credential-name

Name of the key store entity to use as the password.

keystore-password-credential-password

Password for the password key store entity.

Multiple ClickHouse servers#

If you have multiple ClickHouse servers you need to configure one catalog for each server. To add another catalog:

  • Add another properties file to etc/catalog

  • Save it with a different name that ends in .properties

For example, if you name the property file sales.properties, Trino uses the configured connector to create a catalog named sales.

General configuration properties#

The following table describes general catalog configuration properties for the connector:

Property name

Description

Default value

case-insensitive-name-matching

Support case insensitive schema and table names.

false

case-insensitive-name-matching.cache-ttl

1m

case-insensitive-name-matching.config-file

Path to a name mapping configuration file in JSON format that allows Trino to disambiguate between schemas and tables with similar names in different cases.

null

case-insensitive-name-matching.config-file.refresh-period

Frequency with which Trino checks the name matching configuration file for changes.

0 (refresh disabled)

metadata.cache-ttl

Duration for which metadata, including table and column statistics, is cached.

0 (caching disabled)

metadata.cache-missing

Cache the fact that metadata, including table and column statistics, is not available

false

metadata.cache-maximum-size

Maximum number of objects stored in the metadata cache

10000

write.batch-size

Maximum number of statements in a batched execution. Do not change this setting from the default. Non-default values may negatively impact performance.

1000

dynamic-filtering.enabled

Push down dynamic filters into JDBC queries

true

dynamic-filtering.wait-timeout

Maximum duration for which Trino will wait for dynamic filters to be collected from the build side of joins before starting a JDBC query. Using a large timeout can potentially result in more detailed dynamic filters. However, it can also increase latency for some queries.

20s

Domain compaction threshold#

Pushing down a large list of predicates to the data source can compromise performance. Trino compacts large predicates into a simpler range predicate by default to ensure a balance between performance and predicate pushdown. If necessary, the threshold for this compaction can be increased to improve performance when the data source is capable of taking advantage of large predicates. Increasing this threshold may improve pushdown of large dynamic filters. The domain-compaction-threshold catalog configuration property or the domain_compaction_threshold catalog session property can be used to adjust the default value of 1000 for this threshold.

Procedures#

  • system.flush_metadata_cache()

    Flush JDBC metadata caches. For example, the following system call flushes the metadata caches for all schemas in the example catalog

    USE example.myschema;
    CALL system.flush_metadata_cache();
    

Case insensitive matching#

When case-insensitive-name-matching is set to true, Trino is able to query non-lowercase schemas and tables by maintaining a mapping of the lowercase name to the actual name in the remote system. However, if two schemas and/or tables have names that differ only in case (such as «customers» and «Customers») then Trino fails to query them due to ambiguity.

In these cases, use the case-insensitive-name-matching.config-file catalog configuration property to specify a configuration file that maps these remote schemas/tables to their respective Trino schemas/tables:

{
  "schemas": [
    {
      "remoteSchema": "CaseSensitiveName",
      "mapping": "case_insensitive_1"
    },
    {
      "remoteSchema": "cASEsENSITIVEnAME",
      "mapping": "case_insensitive_2"
    }],
  "tables": [
    {
      "remoteSchema": "CaseSensitiveName",
      "remoteTable": "tablex",
      "mapping": "table_1"
    },
    {
      "remoteSchema": "CaseSensitiveName",
      "remoteTable": "TABLEX",
      "mapping": "table_2"
    }]
}

Queries against one of the tables or schemes defined in the mapping attributes are run against the corresponding remote entity. For example, a query against tables in the case_insensitive_1 schema is forwarded to the CaseSensitiveName schema and a query against case_insensitive_2 is forwarded to the cASEsENSITIVEnAME schema.

At the table mapping level, a query on case_insensitive_1.table_1 as configured above is forwarded to CaseSensitiveName.tablex, and a query on case_insensitive_1.table_2 is forwarded to CaseSensitiveName.TABLEX.

By default, when a change is made to the mapping configuration file, Trino must be restarted to load the changes. Optionally, you can set the case-insensitive-name-mapping.refresh-period to have Trino refresh the properties without requiring a restart:

case-insensitive-name-mapping.refresh-period=30s

Non-transactional INSERT#

The connector supports adding rows using INSERT statements. By default, data insertion is performed by writing data to a temporary table. You can skip this step to improve performance and write directly to the target table. Set the insert.non-transactional-insert.enabled catalog property or the corresponding non_transactional_insert catalog session property to true.

Note that with this property enabled, data can be corrupted in rare cases where exceptions occur during the insert operation. With transactions disabled, no rollback can be performed.

Querying ClickHouse#

The ClickHouse connector provides a schema for every ClickHouse database. Run SHOW SCHEMAS to see the available ClickHouse databases:

SHOW SCHEMAS FROM myclickhouse;

If you have a ClickHouse database named web, run SHOW TABLES to view the tables in this database:

SHOW TABLES FROM myclickhouse.web;

Run DESCRIBE or SHOW COLUMNS to list the columns in the clicks table in the web databases:

DESCRIBE myclickhouse.web.clicks;
SHOW COLUMNS FROM clickhouse.web.clicks;

Run SELECT to access the clicks table in the web database:

SELECT * FROM myclickhouse.web.clicks;

Примечание

If you used a different name for your catalog properties file, use that catalog name instead of myclickhouse in the above examples.

Table properties#

Table property usage example:

CREATE TABLE default.trino_ck (
  id int NOT NULL,
  birthday DATE NOT NULL,
  name VARCHAR,
  age BIGINT,
  logdate DATE NOT NULL
)
WITH (
  engine = 'MergeTree',
  order_by = ARRAY['id', 'birthday'],
  partition_by = ARRAY['toYYYYMM(logdate)'],
  primary_key = ARRAY['id'],
  sample_by = 'id'
);

The following are supported ClickHouse table properties from https://clickhouse.tech/docs/en/engines/table-engines/mergetree-family/mergetree/

Property name

Default value

Description

engine

Log

Name and parameters of the engine.

order_by

(none)

Array of columns or expressions to concatenate to create the sorting key. Required if engine is MergeTree.

partition_by

(none)

Array of columns or expressions to use as nested partition keys. Optional.

primary_key

(none)

Array of columns or expressions to concatenate to create the primary key. Optional.

sample_by

(none)

An expression to use for sampling. Optional.

Currently the connector only supports Log and MergeTree table engines in create table statement. ReplicatedMergeTree engine is not yet supported.

Type mapping#

Because Trino and ClickHouse each support types that the other does not, this connector modifies some types when reading or writing data. Data types may not map the same way in both directions between Trino and the data source. Refer to the following sections for type mapping in each direction.

ClickHouse type to Trino type mapping#

The connector maps ClickHouse types to the corresponding Trino types according to the following table:

ClickHouse type to Trino type mapping#

ClickHouse type

Trino type

Notes

Int8

TINYINT

TINYINT, BOOL, BOOLEAN, and INT1 are aliases of Int8

Int16

SMALLINT

SMALLINT and INT2 are aliases of Int16

Int32

INTEGER

INT, INT4, and INTEGER are aliases of Int32

Int64

BIGINT

BIGINT is an alias of Int64

UInt8

SMALLINT

UInt16

INTEGER

UInt32

BIGINT

UInt64

DECIMAL(20,0)

Float32

REAL

FLOAT is an alias of Float32

Float64

DOUBLE

DOUBLE is an alias of Float64

Decimal

DECIMAL

FixedString

VARBINARY

Enabling clickhouse.map-string-as-varchar config property changes the mapping to VARCHAR

String

VARBINARY

Enabling clickhouse.map-string-as-varchar config property changes the mapping to VARCHAR

Date

DATE

DateTime[(timezone)]

TIMESTAMP(0) [WITH TIME ZONE]

IPv4

IPADDRESS

IPv6

IPADDRESS

Enum8

VARCHAR

Enum16

VARCHAR

UUID

UUID

No other types are supported.

Trino type to ClickHouse type mapping#

The connector maps Trino types to the corresponding ClickHouse types according to the following table:

Trino type to ClickHouse type mapping#

Trino type

ClickHouse type

Notes

BOOLEAN

UInt8

TINYINT

Int8

TINYINT, BOOL, BOOLEAN, and INT1 are aliases of Int8

SMALLINT

Int16

SMALLINT and INT2 are aliases of Int16

INTEGER

Int32

INT, INT4, and INTEGER are aliases of Int32

BIGINT

Int64

BIGINT is an alias of Int64

REAL

Float32

FLOAT is an alias of Float32

DOUBLE

Float64

DOUBLE is an alias of Float64

DECIMAL(p,s)

Decimal(p,s)

VARCHAR

String

CHAR

String

VARBINARY

String

Enabling clickhouse.map-string-as-varchar config property changes the mapping to VARCHAR

DATE

Date

TIMESTAMP(0)

DateTime

UUID

UUID

No other types are supported.

Type mapping configuration properties#

The following properties can be used to configure how data types from the connected data source are mapped to Trino data types and how the metadata is cached in Trino.

Property name

Description

Default value

unsupported-type-handling

Configure how unsupported column data types are handled:

  • IGNORE, column is not accessible.

  • CONVERT_TO_VARCHAR, column is converted to unbounded VARCHAR.

The respective catalog session property is unsupported_type_handling.

IGNORE

jdbc-types-mapped-to-varchar

Allow forced mapping of comma separated lists of data types to convert to unbounded VARCHAR

SQL support#

The connector provides read and write access to data and metadata in a ClickHouse catalog. In addition to the globally available and read operation statements, the connector supports the following features:

ALTER SCHEMA#

The connector supports renaming a schema with the ALTER SCHEMA RENAME statement. ALTER SCHEMA SET AUTHORIZATION is not supported.

Performance#

The connector includes a number of performance improvements, detailed in the following sections.

Pushdown#

The connector supports pushdown for a number of operations:

Aggregate pushdown for the following functions:

Примечание

The connector performs pushdown where performance may be improved, but in order to preserve correctness an operation may not be pushed down. When pushdown of an operation may result in better performance but risks correctness, the connector prioritizes correctness.

Predicate pushdown support#

The connector does not support pushdown of any predicates on columns with textual types like CHAR or VARCHAR. This ensures correctness of results since the data source may compare strings case-insensitively.

In the following example, the predicate is not pushed down for either query since name is a column of type VARCHAR:

SELECT * FROM nation WHERE name > 'CANADA';
SELECT * FROM nation WHERE name = 'CANADA';